Inspection Detail
Inspection: 307931428 - Helevator Control Tower, Inc.
Inspection Information - Office: Pr-E-San Juan 0257260
Site Address:
Helevator Control Tower, Inc.
Calle Fidalgo Diaz 1977-E Urb Caldas
San Juan, PR 00908
Mailing Address:
Po Box 362411, San Juan, PR 00936
Union Status: NonUnion
SIC:1796
NAICS: 238290/Other Building Equipment Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/25/2007
Emphasis:
Case Closed: 02/01/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100170737 |
Investigation Summary
On October 6, 2006, Employee #1 and a coworker were working on a hydraulic elevator. They removed a safety valve, causing the release of the elevator piston pressure. The elevator fell and Employee #1 was trapped underneath. He was fatally injured.
Keywords: CHEST, REPAIR, SAFETY RELIEF VALVE, INADEQUATE MAINT, HYDRAULIC ELEVATOR, CAUGHT BETWEEN, STRUCK BY, CONCUSSION, FALLING OBJECT, PRESSURE RELEASE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 307931428 | Fatality | Concussion | Occupation not reported |