Powered by GoogleTranslate

Inspection Detail

Inspection: 307917096 - Splice On

Inspection Information - Office: Wilkes Barre Area Office

 

Inspection Nr: 307917096
Report ID: 0317700
Date Opened: 09/27/2005

Site Address:
Splice On
Rt 154 & Lazytown Rd, Fox Twp
Laporte, PA 18626

Mailing Address:
432 Robbins Road, Greene, NY 13778

Union Status: NonUnion

SIC:4813

NAICS: 517110/Wired Telecommunications Carriers


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/10/2006

Emphasis:

Case Closed: 09/30/2007


Related Activity
Type Activity Nr Safety Health
Accident 101371524
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 1 4 5
Initial Penalty $9,900 $0 $0 $0 $0 $9,900
Current Penalty $1,000 $0 $0 $0 $0 $1,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100268 J03 03/17/2006 04/19/2006 $0 $2,100 $0 04/07/2006 F - Formal Settlement  
2. 01002 Other 19100333 A01 03/17/2006 04/19/2006 $0 $2,100 $0 04/07/2006 F - Formal Settlement  
3. 01003 Other 19100268 F01 03/17/2006 04/19/2006 $0 $2,100 $0 04/07/2006 F - Formal Settlement  
4. 01004 Other 19100268 C 03/17/2006 04/19/2006 $0 $2,100 $0 04/07/2006 F - Formal Settlement  
5. 01005 Serious 19100067 C02 03/17/2006 04/19/2006 $1,000 $1,500 $0 04/07/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201370962
Event: 09/26/2005
Employee Is Electrocuted by Overhead Wires

On September 26, 2005, Employee #1 was installing telephone cable. He was working in an aluminum, fiberglass coated bucket. He raised the bucket and contacted a 14,400 volt unshielded overhead conductor. He was electrocuted and pronounced dead at the scene by the Sullivan County coroner.

Keywords: SHOCK, OVERHEAD POWER LINE, TELECOM WORK, ELECTROCUTED, ELECTRIC SHOCK, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307917096 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close