Inspection: 307835058 - Lin R. Rogers Electrical Contractors, Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 307835058
Report ID: 0418100
Date Opened: 10/15/2004

Site Address:
Lin R. Rogers Electrical Contractors, Inc.
3030 Airport East Road
Macon, GA 31216

Mailing Address:
2050 Marconi Dr., Ste 200, Alpharetta, GA 30005

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/2004

Emphasis:

Case Closed: 03/01/2006


Related Activity
Type Activity Nr Safety Health
Accident 101282192
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $21,500 $0 $12,500 $0 $0 $34,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 04/05/2005 04/22/2005 $0 $7,000 $0 04/25/2005 D - Govt Dismissed  
2. 01002A Serious 19260050 B 04/05/2005 04/15/2005 $0 $2,500 $0 04/25/2005 D - Govt Dismissed  
3. 01002B Serious 19260050 C 04/05/2005 04/15/2005 $0 $0 $0 04/25/2005 D - Govt Dismissed  
4. 01003 Serious 19260451 F03 04/05/2005 04/11/2005 $0 $7,000 $0 04/25/2005 D - Govt Dismissed  
5. 01004 Serious 19260451 G04 IV 04/05/2005 04/15/2005 $0 $2,500 $0 04/25/2005 D - Govt Dismissed  
6. 01005 Serious 19260454 B 04/05/2005 04/15/2005 $0 $2,500 $0 04/25/2005 D - Govt Dismissed  
7. 02001 Repeat 19260021 B02 04/05/2005 05/10/2005 $0 $12,500 $0 04/25/2005 D - Govt Dismissed  

Investigation Summary

Investigation Nr: 201281854
Event: 10/13/2004
Employee is killed in aerial lift failure

On October 13, 2004, Employee #1, an electrician, was hanging conduit in an electrical room while standing on a scissor lift that was elevated approximately 12 feet from the floor. The pins, which allow the scissor portion of the lift to move, failed and he was thrown to the concrete floor. Employee #1 suffered a severe head injury and died 3 days later.

Keywords: EJECTED, HEAD, ELECTRICIAN, CONSTRUCTION, EQUIPMENT FAILURE, LACERATION, FALL, FALL PROTECTION, UNTRAINED, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307835058 Fatality Cut/Laceration Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.