Inspection Detail
Inspection: 3077435 - Superior Coating Corp
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
Superior Coating Corp
10712 Se Harold
Port, OR 97266
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1721
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/12/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/12/1986
Investigation Summary
Employee #1 was working alone inside a Meta water storage tank. The approximate dimensions of the tank were 30 feet long by 10 feet in diameter with one 22 inch opening for access and egress. Employee #1 was spray painting an Engard tank coating material. The cans refer to the material safety data sheets and a technical bulletin regarding the use of this material in a confined space. For some unknown reason the listing warnings were not adhered to, as they relate to the use of non-explosive type electrical equipment and ventilation. A violent explosion blew the victim out of the 22 inch opening. Employee #1 did not have a helper tending hoses outside the tank. Employee #1 was found to be conscious. A coworker in another area, called 911 and Employee #1 was transported to the hospital where he was treated for eight days before dying.
Keywords: BURN, ELECTRICAL, CONFINED SPACE, SPARK, TANK, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3077435 | Fatality | Burn/Scald(Heat) | Painters, construction and maintenance |