Powered by GoogleTranslate

Inspection Detail

Inspection: 307578864 - Jose Chicas Helmer Hernandez

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 307578864
Report ID: 0352410
Date Opened: 06/20/2004

Site Address:
Jose Chicas Helmer Hernandez
702 Ramsey Court, Unit 103
Salisbury, MD 21804

Mailing Address:
4509 Hillbrook Drive, Annandale, VA 22003

Union Status: NonUnion

SIC:1761

NAICS: 238390/Other Building Finishing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/25/2004

Planning Guide: Safety-Construction

Emphasis: S:Construction, S:Electrocution

Case Closed: 11/08/2004


Related Activity
Type Activity Nr Safety Health
Accident 102356292
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,200 $0 $0 $0 $0 $4,200
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 F06 07/30/2004 08/04/2004 $1,000 $2,400 $0 I - Informal Settlement  
2. 01002 Serious 19260454 B 07/30/2004 09/01/2004 $250 $900 $0 I - Informal Settlement  
3. 02001A Serious 19261053 B01 07/30/2004 08/04/2004 $250 $900 $0 I - Informal Settlement  
4. 02001B Serious 19261060 A 07/30/2004 09/01/2004 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202347316
Event: 06/20/2004
Two employees injured when scaffold pole strikes power line

On June 20, 2004, Employees #1, #2, and a coworker were installing a pump jack scaffold on the outside wall of a three-story building. Employee #1 was using both hand to push up over his head a 40 ft long by 11 in. wide Alum-A-Pole support. Employee #2 was holding the base of the pole on the ground with his left foot while he used his hands to pull up on the pump mechanism attached to the system. The coworker was on the roof with a rope tied to the end of pole and was pulling it up when a sudden gust of wind caused him to lose his grip on the rope. The pole fell backward, contacting a 35 ft high, 14,300-volt overhead power line that was 21 ft away. Employee #1 received a severe electrical shock that burned his face and hands and caused muscle damage to both legs. Employee #2 sustained hand and foot injuries when the electric current entered and exited his body. Both employees were med-flighted to Johns Hopkins Bayview Hospital in Baltimore, MD, for treatment.

Keywords: BURN, HIGH WIND, OVERHEAD POWER LINE, STRUCK AGAINST, CONSTRUCTION, METAL POLE, MANUAL MAT HANDLING, ELECTRIC SHOCK, FACE, LOST CONTROL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307578864 Hospitalized injury Electric Shock Carpenters
2 307578864 Hospitalized injury Electric Shock Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close