Powered by GoogleTranslate

Inspection Detail

Inspection: 307457952 - Buena Vista Ventures Llc Dba Riverside Brewing Co

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 307457952
Report ID: 0950633
Date Opened: 09/28/2005

Site Address:
Buena Vista Ventures Llc Dba Riverside Brewing Co
3397 Mission Inn Ave
Riverside, CA 92501

Mailing Address:
3397 Mission Inn Ave, Riverside, CA 92501

Union Status: NonUnion

SIC:2082

NAICS: 312120/Breweries


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/08/2006

Emphasis:

Case Closed: 04/19/2007


Related Activity
Type Activity Nr Safety Health
Accident 102444445
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $5,550 $0 $5,550
Current Penalty $0 $0 $0 $5,550 $0 $5,550
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/08/2006 02/13/2006 $5,000 $5,000 $0 -  
2. 01002 Other 3329 D 02/08/2006 02/13/2006 $550 $550 $0 -  

Investigation Summary

Investigation Nr: 202442117
Event: 04/14/2004
Employee Is Burned When Hot Water Tank Overflows

At approximately 4:00 p.m. on April 14, 2004, Employee #1, a brew master, was cleaning and sanitizing beer kegs with boiling hot water from a hose connected to a hot water tank. A beer keg had not been properly purged to relieve internal pressure, and when the brew master opened the gate valve, the beer keg, pressurized with 16 to 18 psi of carbon dioxide gas, caused boiling hot water in the tank to overflow from the top of the tank. Approximately five gallons of hot boiling water spilled onto Employee #1, causing second degree burns to his legs, back and arms. A coworker came to his aid and drove him to a nearby hospital for emergency medical care. He was treated for his burns and released. Three days later, Employee #1 went to Arrowhead Regional Medical Center, where he was evaluated and admitted to the Burn Ward with second and third degree thermal burns, and hospitalized for ten days.

Keywords: BURN, CLEANING, HOT WATER TANK, BACK, STRUCK BY, ARM, HOT WATER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307457952 Hospitalized injury Burn/Scald(Heat) Bartenders
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close