Inspection: 307454736 - Strong Hold Engineering

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 307454736
Report ID: 0950633
Date Opened: 10/08/2004

Site Address:
Strong Hold Engineering
3421 Gato Court
Riverside, CA 92507

Mailing Address:
2000 Market Street, Riverside, CA 92501

Union Status: NonUnion

SIC:8711

NAICS: 541330/Engineering Services


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/28/2005

Emphasis:

Case Closed: 02/19/2013


Related Activity
Type Activity Nr Safety Health
Accident 101158897
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 6 7
Current Violations 1 1 5 7
Initial Penalty $18,000 $0 $0 $6,115 $0 $24,115
Current Penalty $0 $0 $5,000 $1,115 $0 $6,115
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 342 A 01/28/2005 02/11/2005 $5,000 $5,000 $0 02/22/2005 F - Formal Settlement  
2. 01002 Other 23400023 01/28/2005 02/11/2005 $185 $185 $0 -  
3. 01003 Other 3328 D 01/28/2005 02/11/2005 $185 $185 $0 -  
4. 01004 Other 3577 E 01/28/2005 02/11/2005 $185 $185 $0 -  
5. 01005 Other 3578 G 01/28/2005 02/11/2005 $185 $185 $0 -  
6. 01006 Other 4650 E 01/28/2005 02/11/2005 $375 $375 $0 -  
7. 02001 Serious 3328 B 01/28/2005 02/07/2005 $0 $18,000 $0 02/22/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202439717
Event: 09/24/2004
Employee's Finger Is Amputated in Threading Machine

At approximately 2:10 p.m. on September 24, 2004, Employee #1 was operating a threading machine, a Wheeler Rex, Model Number 6790, Serial Number 784517, to thread a 0.75-in. schedule-80, hydraulic pipe. A coworker was helping him and they had made four threads on two pipes. Employee #1 fed a pipe into the machine but the pipe was not locked. He was trying to close the jaws with his left hand and was holding the pipe with his right hand. He pushed the foot pedal switch with his right foot and the pipe became stuck between the pipe and threading die. His right smallest finger was crushed between the pipe and threading die. His finger was amputated at the hospital.

Keywords: AMPUTATED, FINGER, CAUGHT BY, CAUGHT BETWEEN, CRUSHED, PIPE, STRUCK BY, NIP POINT, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307454736 Hospitalized injury Amputation Managers and administrators, n.e.c
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.