Inspection Detail
Inspection: 307390849 - Sf Muni Railway
Inspection Information - Office: San Francisco District Office
Site Address:
Sf Muni Railway
2500 Mariposa St. Potrero Div.
San Francisco, CA 94110
Mailing Address:
1 South Van Ness, 7th Flr, San Francisco, CA 94103
Union Status: Union
SIC:4111
NAICS: 485113/Bus and Other Motor Vehicle Transit Systems
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/01/2005
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/20/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361565401 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $21,150 | $0 | $0 | $350 | $0 | $21,500 |
| Current Penalty | $21,150 | $0 | $0 | $350 | $0 | $21,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 2940 C | 02/07/2005 | 04/12/2005 | $350 | $350 | $0 | P - Petition to Mod Abatement | ||
| 2. | 02001 | Serious | 29400001 A | 02/07/2005 | 04/12/2005 | $3,150 | $3,150 | $0 | P - Petition to Mod Abatement | ||
| 3. | 03001 | Serious | 29400002 A | 02/07/2005 | 05/17/2005 | $18,000 | $18,000 | $0 | A - Amendment |
Investigation Summary
On August 12, 2004, Employee #1 was working for a railway as an electrical transit system mechanic. He was troubleshooting a new articulating coach. He drove it from the yard to the house. It stalled and he got off the coach to check some of the connections. He wanted to disconnect a 2-in. metallic XLR connector from a compartment located inside the rear of the coach. He was not wearing approved gloves with sleeves for energized electrical work and the fuse box terminals were not guarded or shielded. He was removing a tightly secured plug and heard a noise. He thought someone had activated the coach and quickly released the metallic plug and it came in contact with the fuse panel that was approximately 10-in away. The contact shorted the positive and negative terminals of the 600 volt, 30 amp fuse panel that was still energized. Employee #1 was hospitalized for second and third degree burns to both forearms.
Keywords: BURN, PPE, ELECTROCUTED, STRUCK AGAINST, LOCKOUT, ELEC CIRC PART--MISC, ELECTRIC SHOCK, ELECTRICAL CABINET
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 307390849 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, mechanics and repairers |