Powered by GoogleTranslate

Inspection Detail

Inspection: 307337204 - Central Chevrolet

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 307337204
Report ID: 0950614
Date Opened: 04/12/2005

Site Address:
Central Chevrolet
36849 San Pedro Drive
Fremont, CA 94536

Mailing Address:
, , 00000

Union Status: Union

SIC:7532

NAICS: 811121/ Automotive Body, Paint, and Interior Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/29/2005

Emphasis:

Case Closed: 06/29/2009


Related Activity
Type Activity Nr Safety Health
Accident 361628126
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 2 2 4
Initial Penalty $26,100 $0 $0 $325 $0 $26,425
Current Penalty $2,475 $0 $0 $625 $0 $3,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3556 A 07/01/2005 07/19/2005 $250 $325 $0 07/20/2005 F - Formal Settlement  
2. 02001 Other 3314 C 07/01/2005 07/19/2005 $375 $20,250 $0 07/20/2005 F - Formal Settlement  
3. 03001 Serious 3314 G 07/01/2005 07/19/2005 $2,250 $2,925 $0 07/20/2005 F - Formal Settlement  
4. 04001 Serious 3314 J01 07/01/2005 07/19/2005 $225 $2,925 $0 07/20/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201505583
Event: 04/12/2005
Auto Body Mechanic Is Killed by Descending Lift

In the morning of April 12, 2005, an auto body mechanic was working on a Honda Accord. The vehicle was raised approximately 30 in. by an automotive hydraulic lift known as a "Snap-On Mid-Rise Auto Lift." The mechanic attempted to lower the car by operating the control lever on the power pack of the hydraulic lift. The down lever did not function so the employee disconnected the power pack and the hydraulic hose. He then blew air with his mouth through the hose to check if the hose was clear. Satisfied that the hose was clear, the employee maneuvered himself under the vehicle and unscrewed several treads of the velocity fuse assembly. Hydraulic fluid began to leak from the threaded fitting. In order to prevent oil from spilling on the floor, the employee re-tightened the velocity fuse but it blew-off from its housing. The car descended very rapidly and pinned the employee to the floor. When emergency medical services arrived, they took the auto body mechanic to Eden Medical Center, where he was pronounced dead.

Keywords: HYDRAULIC LIFT, AUTOMOTIVE REPAIR, PINNED, HYDRAULIC FLUID, TORSO, EQUIPMENT FAILURE, LOCKOUT, CRUSHED, AUTOMOBILE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307337204 Fatality Fracture Automobile mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close