Powered by GoogleTranslate

Inspection Detail

Inspection: 307234351 - Anchor Pointe Boat-A-Minium Association, Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 307234351
Report ID: 0524700
Date Opened: 09/01/2004

Site Address:
Anchor Pointe Boat-A-Minium Association, Inc.
10905 Corduroy Rd.
Curtice, OH 43412

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4493

NAICS: 713930/Marinas


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/01/2004

Emphasis:

Case Closed: 12/30/2004


Related Activity
Type Activity Nr Safety Health
Complaint 204968101 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100252 A02 XIIIC 09/14/2004 10/01/2004 $300 $750 $0 I - Informal Settlement  
2. 01002 Serious 19100252 A03 I 09/14/2004 09/21/2004 $300 $750 $0 I - Informal Settlement  
3. 01003 Serious 19101200 E01 09/14/2004 10/08/2004 $300 $750 $0 I - Informal Settlement  
4. 01004 Serious 19101200 G08 09/14/2004 09/17/2004 $300 $750 $0 I - Informal Settlement  
5. 01005 Serious 19101200 H01 09/14/2004 09/24/2004 $300 $750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202086872
Event: 08/24/2004
Employee is burned while cutting barrel

On August 24, 2004, Employee #1 was torch-cutting the lid off of a metal barrel. The barrel previously contained propylene glycol, and was not cleaned or purged prior to the cutting. When the cutting began, an explosion occurred. Employee #1 received second- and third-degree burns to his face and was hospitalized for treatment. The employer had no hazard communication, cutting safety, or training programs in place.

Keywords: BURN, FLAMMABLE LIQUID, DRUM, FIRE, TORCH, EXPLOSION, PURGING, FACE, UNTRAINED, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307234351 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close