Inspection: 307200204 - Better Times Corp.

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 307200204
Report ID: 0950636
Date Opened: 11/24/2008

Site Address:
Better Times Corp.
13060 Firestone Blvd
Santa Fe Springs, CA 90670

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2269

NAICS: 313312/Textile and Fabric Finishing (except Broadwoven Fabric) Mills


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/2009

Emphasis:

Case Closed: 01/02/2010


Related Activity
Type Activity Nr Safety Health
Accident 101805448
Complaint 206248247 Yes Yes
Complaint 206248254 Yes Yes
Complaint 206248395 Yes Yes
Complaint 206248403 Yes Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 1 3 4
Initial Penalty $32,510 $0 $0 $580 $0 $33,090
Current Penalty $14,400 $0 $0 $525 $0 $14,925
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3382 A 05/07/2009 06/09/2009 $225 $305 $0 05/19/2009 F - Formal Settlement  
2. 01002 Other 3664 A 05/07/2009 06/09/2009 $100 $275 $0 05/19/2009 F - Formal Settlement  
3. 02001 Serious 3203 A 05/07/2009 05/21/2009 $0 $3,710 $0 05/19/2009 F - Formal Settlement Citation has been deleted.
4. 03001 Other 5194 H01 05/07/2009 05/21/2009 $200 $14,400 $0 05/19/2009 F - Formal Settlement  
5. 04001 Serious 5417 D 05/07/2009 05/21/2009 $14,400 $14,400 $0 05/19/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202475554
Event: 11/08/2008
Burn - Electric Drill Ignites Solvent Vapors

An employee was mixing paint with light hydrotreated petroleum naphtha (CAS No. 64742-49-0). As directed by his employer, he was using a Milwaukee Magnum Hole-Shooter drill (Model No. CIJD; Serial No. 592 191 4567) with a mixing attachment to mix the paint. The electric drill ignited vapors from the solvent, and the ensuing explosion burned the employee's hand. He was hospitalized for 1 week at a burn center with two skin-graft surgeries. The injured employee, who had not been following the owner's manual instructions not to use the drill in the presence of flammable atmospheres, was not adequately trained in the material safety data sheet for the solvent or in the precautions in the power tool owner's manual.

Keywords: BURN, E GI V, ELECTRICAL, FLAMMABLE VAPORS, PAINT, EXPLOSION, ELECTRIC DRILL, EQUIPMENT APPROVAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307200204 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.