Inspection Detail
Inspection: 307188383 - Adel Wiggins Group Of Transdigm, Inc.
Inspection Information - Office: Monrovia District Office
Site Address:
Adel Wiggins Group Of Transdigm, Inc.
5000 Triggs St
Commerce, CA 90022
Mailing Address:
, , 00000
Union Status: Union
SIC:3499
NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/26/2008
Emphasis:
Case Closed: 11/21/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101804672 | ||
| Complaint | 206246993 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 5 | 8 | |||
| Current Violations | 3 | 5 | 8 | |||
| Initial Penalty | $27,000 | $0 | $0 | $2,520 | $0 | $29,520 |
| Current Penalty | $20,970 | $0 | $0 | $450 | $0 | $21,420 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 11/26/2008 | 12/29/2008 | $0 | $420 | $0 | 12/26/2008 | F - Formal Settlement | |
| 2. | 01002 | Other | 3273 A | 11/26/2008 | 12/29/2008 | $0 | $420 | $0 | 12/26/2008 | F - Formal Settlement | |
| 3. | 01003 | Other | 3328 G | 11/26/2008 | 12/29/2008 | $0 | $280 | $0 | 12/26/2008 | F - Formal Settlement | |
| 4. | 01004 | Other | 5143 A05 | 11/26/2008 | 12/29/2008 | $225 | $700 | $0 | 12/26/2008 | F - Formal Settlement | |
| 5. | 01005 | Other | 5144 C | 11/26/2008 | 12/29/2008 | $225 | $700 | $0 | 12/26/2008 | F - Formal Settlement | |
| 6. | 02001 | Serious | 4075 A | 11/26/2008 | 12/06/2008 | $270 | $4,500 | $0 | 12/26/2008 | F - Formal Settlement | |
| 7. | 03001 | Serious | 4184 B | 11/26/2008 | 12/06/2008 | $2,700 | $4,500 | $0 | 12/26/2008 | F - Formal Settlement | |
| 8. | 04001 | Serious | 5549 A | 11/26/2008 | 12/06/2008 | $18,000 | $18,000 | $0 | 12/26/2008 | F - Formal Settlement |
Investigation Summary
On May 30, 2008, Employee #1, a machine repair lead, was disposing of approximately two quarts of a flammable hazardous solvent waste. The flammable solvent was used as a cleaning agent in an ink jet printer. Employee #1 transported the flammable hazardous solvent waste to a 175 gallon water evaporator for disposal. The evaporator was on and the liquid levels were low. The employer did not ensure that employees received adequate training nor did they ensure that the proper disposal procedure was being utilized by employees. Employee #1 lifted the container of 2-Butanone to the evaporator and there was an ignition and a fire. He sustained first, second and third degree burns to his head, hands, and forearms. Employee #1 was hospitalized.
Keywords: BURN, HEAD, VAPOR, FIRE, FOREARM, IGNITION SYSTEM, UNTRAINED, HAND, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 307188383 | Hospitalized injury | Burn/Scald(Heat) | Industrial machinery repairers |