Powered by GoogleTranslate

Inspection Detail

Inspection: 307185827 - Nickent Golf Equipment Corporation

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 307185827
Report ID: 0950636
Date Opened: 08/15/2007

Site Address:
Nickent Golf Equipment Corporation
19888 Quiroz Ct.
Walnut, CA 91789

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3949

NAICS: 339920/Sporting and Athletic Goods Manufacturing


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/12/2008

Emphasis:

Case Closed: 09/01/2010


Related Activity
Type Activity Nr Safety Health
Accident 101803039
Complaint 206241317 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 2 4
Initial Penalty $7,200 $0 $0 $5,655 $0 $12,855
Current Penalty $7,200 $0 $0 $5,655 $0 $12,855
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/13/2008 03/17/2008 $5,000 $5,000 $0 -  
2. 01002 Other 3203 A 02/13/2008 03/17/2008 $655 $655 $0 -  
3. 02001 Serious 23400023 02/13/2008 02/23/2008 $3,600 $3,600 $0 -  
4. 03001 Serious 23400016 C 02/13/2008 02/23/2008 $3,600 $3,600 $0 -  

Investigation Summary

Investigation Nr: 202474342
Event: 01/08/2007
Employee Receives Burn from Electrical Panel

On January 8, 2007, an employee and two coworkers were sorting golf clubs. The employee and the coworkers had been at this site for approximately one week. There was an electrical panel FDP-BDP-MSP Switchboard, 277/480 volts in the area, protected by guard rails in front. The employee and the coworkers were stacking golf clubs against the guard rail of the electrical panel. There was an opening on the bottom left side of the panel, where a covering had become loose and was hanging. The employee was moving sorting golf clubs in the area, when the panel flashed. The employee received burn and was hospitalized. The coworkers were outside of the area. The employee's supervisor was in another area of the warehouse. He was aware that his employees were sorting and were working in the area, but unaware that they were using the guard rail of the electrical panel. The supervisor thought that the electrical panel was not energized. An electrician, who was the first to work on the panel, stated that it was a possibility that the loose cover of the electrical panel had fallen in, and come into contact with the 3-phase bus bars, causing the explosion.

Keywords: BURN, ELEC CIRC PART--MISC, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307185827 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.