Inspection: 307169359 - Cooling Connection

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 307169359
Report ID: 0950642
Date Opened: 08/14/2006

Site Address:
Cooling Connection
1950 East 20th Street
Los Angeles, CA 90058

Mailing Address:
1350 East 41st Street, Los Angeles, CA 90011

Union Status: NonUnion

SIC:3585

NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/20/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/10/2009


Related Activity
Type Activity Nr Safety Health
Accident 102467727
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $13,500 $0 $0 $6,050 $0 $19,550
Current Penalty $13,500 $0 $0 $6,050 $0 $19,550
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 11/17/2006 12/20/2006 $5,000 $5,000 $0 02/02/2007 J - ALJ Decision  
2. 01002 Other 3203 A 11/17/2006 12/20/2006 $350 $350 $0 02/02/2007 J - ALJ Decision  
3. 01003 Other 3276 A01 11/17/2006 12/20/2006 $350 $350 $0 02/02/2007 J - ALJ Decision  
4. 01004 Other 1675 I 11/17/2006 12/20/2006 $350 $350 $0 02/02/2007 J - ALJ Decision  
5. 02001 Serious 1675 E 11/17/2006 11/27/2006 $13,500 $13,500 $0 02/02/2007 J - ALJ Decision  

Investigation Summary

Investigation Nr: 202452850
Event: 07/29/2006
Employee Fractures Legs in Fall from Ladder

On July 29, 2006, Employee #1 and three other employees were attempting to bolt down a cooling unit, which they installed previously. Two folded A-frame ladders were used by the crew to gain an access to the attic. One ladder, which was placed on top of a storage rack slipped, while Employee #1 was ascending the ladder. As the result, Employee #1 fell approximately 142 in. off the top shelf of the storage rack, struck his face against an electrical junction box on his way down, and landed, facing down, on the floor. He fractured his legs. Employee #1 was immediately taken to County USC Medical Center by the paramedics and was hospitalized. The accident was caused by not placing all ladder feet firmly on a substantial base, before allowing employees to use it.

Keywords: ATTIC, FRACTURE, LADDER, SLIP, STRUCK AGAINST, BOLT, FALL, STORAGE RACK, FACE, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307169359 Hospitalized injury Fracture Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.