Inspection Detail
Inspection: 307161414 - Three G'S Inc
Inspection Information - Office: Long Beach District Office
Site Address:
Three G'S Inc
4920 S Boyle
Vernon, CA 90058
Mailing Address:
22695 Old Canal Rd, Yorba Linda, CA 92887
Union Status: NonUnion
SIC:7361
NAICS: 541612/Human Resources and Executive Search Consulting Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/26/2004
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/26/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101055622 | ||
| Accident | 101055630 | ||
| Accident | 101055648 |
Investigation Summary
At approximately 12:55 p.m. on May 18, 2004, Employee #1, a mechanic, was contracted out by his primary employer to a company engaged in performing salvage material services for various customers. His primary employer specializes in PEO labor leasing, providing the workforce and supervision for other businesses. Employee #1 was assigned to relocate and install the controls of a C-Stonehoni, Inc., vertical bailer. He began by disconnecting the power source to the machine and removed its fuses. Employee #1 then relocated the bailer's controls and worked to rewire them. After performing this task and energizing the machine, Employee #1 noticed that there were some loose wires. As he turned around to disconnect the machine from the main energy source in order to tighten the loose wires, he accidentally touched one of the wires. Employee #1 was electrocuted and collapsed. A coworker that was nearby and had been assisting Employee #1 earlier in the task observed him fall to the ground and ran to the main disconnect to shut the power off. The coworker then notified his manager of the accident, who immediately contacted emergency services. Emergency personnel, upon arrival, transported Employee #1 to County USC Medical, where he was hospitalized and treated for third degree burns on his left wrist.
Keywords: BURN, REPAIR, PPE, ELECTRICIAN, LOCKOUT, ELECTRIC CORD, HAND, WRIST
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 307161414 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, mechanics and repairers |