Powered by GoogleTranslate

Inspection Detail

Inspection: 307153361 - City Of Scottsdale, Parks, Recreation & Facilities

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 307153361
Report ID: 0950411
Date Opened: 12/09/2003

Site Address:
City Of Scottsdale, Parks, Recreation & Facilities
3939 North Drinkwater Blvd
Scottsdale, AZ 85251

Mailing Address:
7447 East Indian School Road, Suite 225, Scottsdale, AZ 85251

Union Status: NonUnion

SIC:9199

NAICS: 921190/Other General Government Support


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Health

Close Conference: 12/09/2003

Emphasis:

Case Closed: 03/04/2004


Related Activity
Type Activity Nr Safety Health
Accident 101992972
Referral 201985090 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $30,000 $0 $0 $0 $0 $30,000
Current Penalty $15,000 $0 $0 $0 $0 $15,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 D01 02/09/2004 03/01/2004 $2,500 $5,000 $0 I - Informal Settlement  
2. 01002 Serious 19100332 B01 02/09/2004 02/12/2004 $2,500 $5,000 $0 I - Informal Settlement  
3. 01003 Serious 19100333 A 02/09/2004 02/12/2004 $2,500 $5,000 $0 I - Informal Settlement  
4. 01004 Serious 19100335 A01 I 02/09/2004 02/12/2004 $2,500 $5,000 $0 I - Informal Settlement  
5. 01005 Serious 19100335 A02 I 02/09/2004 02/12/2004 $2,500 $5,000 $0 I - Informal Settlement  
6. 01006 Serious 19100335 A02 II 02/09/2004 02/12/2004 $2,500 $5,000 $0 I - Informal Settlement  
7. 02001 Other 19100335 A01 II 02/09/2004 03/01/2004 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201991262
Event: 12/03/2003
Employee Receives Burn in Electrical Panel Explosion

On December 3, 2003, an employee was addressing a "trouble call" within City Hall for the City of Scottsdale. After responding, he checked the variable frequency drive, VFD, for Air Handler Number 2. He verified that power was engaged and supplying power to the VFD supplied to the air handler. He proceeded to the electrical room in the basement of City hall and after disengaging the circuit on the outside of the panel, he opened the panel door. The three fuses were verified to be in proper working order. The panel door was closed again the switch was reengaged. He then opened, using by-pass, the panel door in the energized mode. He again checked the voltage and no reading was detected on the multimeter. Since there was no power being detected on the line or load side of the fuses, he assumed all power was off in the box. On the load side of the fuse, a small lug nut was tightened to ensure proper contact. Although the fuses were detecting as working properly, he decided to change the fuses believing that the installation of the new fuses could restore power. After returning with the new fuses, he pulled the three fuses beginning with the bottom fuse. After pulling the top fuse with electrically rated fuse pullers, the metal clip holding the line side of the fuse broke away from the mounting bracket. The clip however, was still attached to the panel via a small copper wire. While still holding the fuse pullers, he was able to reach behind him and picked up needle nose pliers from his tool bag. He used the pliers to secure the clip and was able to pull the fuse from the clip. While he did that, he recalled having seeing a spark generated between the fuse and metal clip. He then closed the panel door to deenergize the panel, but the door would not close and the switch box remained energized. He reset the three fuses in place using the fuse pullers. The top fuse was placed in, and while still loose, appeared to be in place, other clip was still secured to the panel. He attempted to call a supervisor to alert him that there was a problem. He contacted the Facilities Maintenance Director and he stated that an electrician would be sent immediately to the scene. The employee returned to the mechanical room. There, he met another a coworker, a HVAC technician, who was sent to the same scene responding to a different trouble call with the HVAC unit, Air Handler Number 1, and specifically, the City Attorney's office located at City Hall. The employee proceeded to demonstrate to the coworker the diagnostic steps he had performed in hopes that the coworker could verify the procedures he had taken. With the three) fuses in place, the employee closed the panel door and deenergized the panel, waited a few moments, and reenergized the panel. He opened the door and checked the three fuses again. Again, no voltage was detected. The employee and the coworker both determined that the switch must be bad and they would wait for an electrician. Not wanting to leave the panel in the energized position, the employee manually activated the mechanical slide was activated by the outside disconnect switch. He pulled out his standard channel locks and used those to grab onto the knob extending down from the slide. As he attempted to move the slide towards the right and put force attempting to move the slide, the panel exploded. The employee was hospitalized and treated for burns.

Keywords: BURN, ELECTRICAL CABINET, ELECTRICAL FAULT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307153361 Hospitalized injury Burn/Scald(Heat) Mechanical engineering technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close