Powered by GoogleTranslate

Inspection Detail

Inspection: 307131003 - Mt Picture Display Corp. Of America

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 307131003
Report ID: 0522000
Date Opened: 10/23/2003

Site Address:
Mt Picture Display Corp. Of America
1400 W. Market St.
Troy, OH 45373

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3651

NAICS: 334310/Audio and Video Equipment Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/30/2003

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/22/2004


Related Activity
Type Activity Nr Safety Health
Accident 361917768
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $15,000 $0 $0 $0 $0 $15,000
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 D01 12/01/2003 12/18/2003 $0 $5,000 $0 12/18/2003 F - Formal Settlement Citation has been deleted.
2. 01002A Serious 19100303 G02 I 12/01/2003 12/18/2003 $5,000 $5,000 $0 12/18/2003 F - Formal Settlement  
3. 01002B Serious 19100333 A 12/01/2003 12/18/2003 $0 $0 $0 12/18/2003 F - Formal Settlement Citation has been deleted.
4. 01003 Serious 19100332 B01 12/01/2003 12/18/2003 $0 $5,000 $0 12/18/2003 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201953650
Event: 10/23/2003
Employee Is Electrocuted While Testing Television Tube

On October 23, 2003, an employee while testing a television tube touched a high voltage lead burning the right hand and left side front of the hip resulting in an electrocution. These were the entrance and exit points. The equipment involved in the fatality had been in operation for over a year, a similar machine had been in operation for over six years. The operation was a high voltage picture tube testing station where an employee handled a two sided lead inserting it into a television picture tube.

Keywords: BURN, ELECTROCUTED, ELECTRIC SHOCK, HAND, HIP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307131003 Fatality Electric Shock Production inspectors, checkers and examiners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.