Powered by GoogleTranslate

Inspection Detail

Inspection: 307073916 - Air Power Heating Air Conditioning & Sheet Metal

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 307073916
Report ID: 0316400
Date Opened: 01/07/2006

Site Address:
Air Power Heating Air Conditioning & Sheet Metal
122 Luther Jones Road
Kearneysville, WV 25430

Mailing Address:
Po Box 375, Kearneysville, WV 25430

Union Status: NonUnion

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Health

Close Conference: 03/24/2006

Emphasis:

Case Closed: 07/27/2006


Related Activity
Type Activity Nr Safety Health
Accident 100631191
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $2,850 $0 $0 $1,900 $0 $4,750
Current Penalty $2,850 $0 $0 $1,900 $0 $4,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100101 B 04/19/2006 04/25/2006 $750 $750 $0 -  
2. 01002 Serious 19100102 A 04/19/2006 04/25/2006 $750 $750 $0 -  
3. 01003A Serious 19100333 B02 04/19/2006 04/25/2006 $600 $600 $0 -  
4. 01003B Serious 19100333 B02 04/19/2006 04/25/2006 $0 $0 $0 -  
5. 01004A Serious 19101200 E01 04/19/2006 04/27/2006 $750 $750 $0 -  
6. 01004B Serious 19101200 G01 04/19/2006 04/27/2006 $0 $0 $0 -  
7. 01004C Serious 19101200 H 04/19/2006 04/27/2006 $0 $0 $0 -  
8. 02001 Other 19040039 A 04/19/2006 04/24/2006 $1,500 $1,500 $0 -  
9. 03001 Other 19030019 C01 06/30/2006 08/02/2006 $400 $400 $0 -  

Investigation Summary

Investigation Nr: 200631315
Event: 01/04/2006
Employee Is Killed While Replacing Heat Pump

On January 4, 2006, Employee #1 was replacing a residential heat pump unit. Electric power to the unit had been turned off at the residence's service panelboard. Before leaving the site, a coworker observed Employee #1 testing the electric circuit with a meter. Employee #1 was later found slumped against the side of the unit, unresponsive, with a burning acetylene torch in his hand, and the clothing on his right side on fire. After the fire was dowsed, Employee #1 was pronounced dead at the scene. The medical examiner's report attributed the death to a heat pump explosion, Freon exposure and thermal burn injuries. Evidence at the site indicated the electric conductors to the unit had been disconnected and pulled from the unit. The contents of the Freon system had been pumped to a Freon recovery cylinder and the Freon lines had been separated. Employee #1 had apparently been using the torch to melt ice that had formed around the unit.

Keywords: BURN, MAINTENANCE, REPAIR, ACETYLENE TORCH, ACETYLENE, FIRE, FREON, LOCKOUT, TORCH, PUMP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 307073916 Fatality Poisoning(Systemic) Heating, air conditioning, and refrig. mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close