Inspection Detail
Inspection: 307035220 - Rodriguez Custom Painting
Inspection Information - Office: San Diego District Office
Site Address:
Rodriguez Custom Painting
13145 Ridgedale Drive
Poway, CA 92064
Mailing Address:
14231 Garden Road, Suite 12, Poway, CA 92064
Union Status: NonUnion
SIC:1721
NAICS: 238320/Painting and Wall Covering Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/05/2007
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/08/2013
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101062719 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 13 | 17 | |||
| Current Violations | 3 | 14 | 17 | |||
| Initial Penalty | $38,250 | $0 | $0 | $9,495 | $0 | $47,745 |
| Current Penalty | $11,700 | $0 | $0 | $4,150 | $0 | $15,850 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 02/05/2007 | 03/10/2007 | $1,500 | $5,000 | $0 | 03/01/2007 | F - Formal Settlement | |
| 2. | 01002 | Other | 1509 A | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 3. | 01003 | Other | 1509 B | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 4. | 01004 | Other | 1512 C01 | 02/05/2007 | 03/10/2007 | $150 | $280 | $0 | 03/01/2007 | F - Formal Settlement | |
| 5. | 01005 | Other | 1512 E | 02/05/2007 | 03/10/2007 | $250 | $465 | $0 | 03/01/2007 | F - Formal Settlement | |
| 6. | 01006 | Other | 5144 C01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 7. | 01007 | Other | 5144 E01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 8. | 01008 | Other | 5144 F01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 9. | 01009 | Other | 5144 G01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 10. | 01010 | Other | 5144 H01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 11. | 01011 | Other | 5144 K01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 12. | 01012 | Other | 5194 E01 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 13. | 01013 | Other | 5194 G08 | 02/05/2007 | 03/10/2007 | $150 | $375 | $0 | 03/01/2007 | F - Formal Settlement | |
| 14. | 02001 | Serious | 5194 H01 E | 02/05/2007 | 03/10/2007 | $4,500 | $6,750 | $0 | 03/01/2007 | F - Formal Settlement | |
| 15. | 03001 | Serious | 5144 D01 | 02/05/2007 | 02/14/2007 | $4,500 | $6,750 | $0 | 03/01/2007 | F - Formal Settlement | |
| 16. | 04001 | Other | 5416 C | 02/05/2007 | 02/14/2007 | $750 | $6,750 | $0 | 03/01/2007 | F - Formal Settlement | |
| 17. | 05001 | Serious | 1534 B | 02/05/2007 | 02/14/2007 | $2,700 | $18,000 | $0 | 03/01/2007 | F - Formal Settlement |
Investigation Summary
At approximately 4:30 p.m. on August 23, 2006, Employee #1 and a coworker were painting a kitchen of a single family home. Before work began, the supervisor brought two five gallon buckets of white wood undercoat and one five gallon bucket of lacquer thinner to the jobsite. The supervisor then instructed Employee #1 and the coworker to use for painting with a spray assembly. The kitchen of the residence was masked off from the other portions of the house creating a tent-like atmosphere. As Employee #1 was spraying underneath a wall mounted oven, an explosion occurred. A fire ball formed and struck the back kitchen wall, igniting the plastic sheeting used for masking off the area. Emergency services were contacted, and Employee #1 was taken to UCSD Burn Center, where he was hospitalized and treated for serious burn injuries. The accident investigation revealed that the explosion occurred due to an oven pilot light that was the source of ignition. The flammable vapor of the paint allowed the atmosphere to exceed the allowable Lower Explosive Limit (LEL), causing the explosion when introduced to the ignition source. The atmosphere was not tested prior to the explosion.
Keywords: BURN, FLAMMABLE VAPORS, CONSTRUCTION, PAINT, EXPLOSION, PAINTER, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 307035220 | Hospitalized injury | Burn(Chemical) | Painters, construction and maintenance |
Translate