Powered by GoogleTranslate

Inspection Detail

Inspection: 306952847 - Ouellette Plumbing & Heating Corp.

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 306952847
Report ID: 0111700
Date Opened: 11/15/2005

Site Address:
Ouellette Plumbing & Heating Corp.
Mclaughlin Cluster - 2 Maynard St.
Hanover, NH 03755

Mailing Address:
36 Dorset Lane, Williston, VT 05495

Union Status: Union

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/15/2006

Emphasis:

Case Closed: 04/14/2006


Related Activity
Type Activity Nr Safety Health
Referral 200617736 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1 2
Initial Penalty $4,750 $0 $0 $0 $0 $4,750
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 03/22/2006 03/26/2006 $3,500 $3,500 $0 -  
2. 01002 Other 19260350 J 03/22/2006 03/26/2006 $0 $1,250 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200612026
Event: 11/15/2005
Employees Are Injured in Rack Collapse

On November 15, 2005, Employees #1 through #6 were loading a Unistrut rack with copper pipe of varying sizes. The rack collapsed Employee #1, who was then hospitalized with fractures. Employees #2 trough #6 sustained various injuries during the rescue of Employee #1. The rack had been improperly constructed in three ways: (1) single through-bolts were used to assemble some of the horizontal and vertical members within the rack, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, (2) the horizontal braces were connected with single bolts, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, and (3) diagonal braces were not used to stabilize the frames.

Keywords: COLLAPSE, EQUIPMENT FAILURE, BOLT, BRACE, PIPE, STORAGE RACK, STRUCK BY, STORAGE AREA

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
3 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
4 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
5 306952847 Hospitalized injury Fracture Occupation not reported
6 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.