Inspection Detail
Inspection: 306830431 - A-C Electric Company, Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
A-C Electric Company, Inc.
234 Seven Farms Drive
Charleston, SC 29417
Mailing Address:
Po Box 548, Hollywood, SC 29449
Union Status: NonUnion
SIC:1731
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/09/2003
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/13/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100374289 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 5 | ||||
| Current Violations | 5 | 5 | ||||
| Initial Penalty | $7,250 | $0 | $0 | $0 | $0 | $7,250 |
| Current Penalty | $7,250 | $0 | $0 | $0 | $0 | $7,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 02001 | Serious | 19260021 B02 | 09/23/2003 | 10/27/2003 | $875 | $875 | $0 | - | ||
| 2. | 02002 | Serious | 19260405 B01 | 09/23/2003 | 09/26/2003 | $500 | $500 | $0 | - | ||
| 3. | 02003 | Serious | 19260405 D | 09/23/2003 | 10/27/2003 | $875 | $875 | $0 | - | ||
| 4. | 02004 | Serious | 19260416 A01 | 09/23/2003 | 10/27/2003 | $2,500 | $2,500 | $0 | - | ||
| 5. | 02005 | Serious | 19260417 C | 09/23/2003 | 10/27/2003 | $2,500 | $2,500 | $0 | - |
Investigation Summary
On August 25, 2003, Employee #1 was on a 10 ft tall stepladder, installing light fixtures in the second-floor hallway of a building under construction. He was working above the ceiling grid and completing the final step of installation, which involved connecting the hot wires and placing a wire nut on the connection. Employee #1 was engaged in this process when his left hand contacted the energized 277 volt conductors. Employee #1 suffered an electric shock and a small burn. The shock caused him to fall from the ladder, striking his head on the concrete floor as he landed. Emergency Services responded and transported Employee #1 to the hospital, where he was pronounced dead due to head injuries suffered when he fell. At the time of the accident, the breaker controlling the lighting being installed was still energized.
Keywords: HEAD, INSTALLING, ELECTRICAL, STEPLADDER, WORK RULES, STRUCK AGAINST, CONSTRUCTION, LIGHTING, ELEC CIRC PART--MISC, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 306830431 | Fatality | Other | Electricians |