Powered by GoogleTranslate

Inspection Detail

Inspection: 306794983 - Winnebagoland Security Service Inc.

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 306794983
Report ID: 0521100
Date Opened: 03/02/2004

Site Address:
Winnebagoland Security Service Inc.
300 E. Breed St.
Chilton, WI 53014

Mailing Address:
P.O. Box 1692, Fond Du Lac, WI 54936

Union Status: NonUnion

SIC:7381

NAICS: 561612/Security Guards and Patrol Services


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/03/2004

Emphasis:

Case Closed: 06/10/2004


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19101200 E01 05/03/2004 05/21/2004 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200650901
Event: 02/21/2004
Four employees sustain burns when vapors explode

On February 21, 2004, Employees #1, #2, #3, and #4 were cleaning a tank, which was part of a compressor used to recover gas mixed with methylacetylene-propadiene and liquid propane from rework cylinders in a production process. The cleaning was being done in a separate area of the plant from the production operation. The gas mixed with methylacetylene-propadiene was bottled prior to the cleaning, and a tarry sludge accumulated in the tank's bottom from the methylacetylene-propadiene operation. When the tank was opened and tank cleaning began, the sludge was released. A nearby located propane heater for the steam heated a pressure washing unit, which apparently ignited the vapors emanating from the tank and the sludge into the work room. Employees #1, #2, and #4 were hospitalized with 1st and 2nd degree burns. Employee #3 was treated for injuries, however he was not hospitalized.

Keywords: COMPRESSOR, CLEANING, EXPLOSION, TANK, BURN, GAS, ARM, SLUDGE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306794983 Hospitalized injury Burn/Scald(Heat) Guards and police, excluding public service
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.