Powered by GoogleTranslate

Inspection Detail

Inspection: 306721143 - Rockford Blacktop Construction Co.

Inspection Information - Office: Naperville Area Office

 

Inspection Nr: 306721143
Report ID: 0521400
Date Opened: 08/22/2003

Site Address:
Rockford Blacktop Construction Co.
5290 Nimtz Road
Loves Park, IL 61111

Mailing Address:
, , 00000

Union Status: Union

SIC:1611

NAICS: 237310/ Highway, Street, and Bridge Construction


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/17/2003

Emphasis: S:Construction

Case Closed: 09/29/2004


Related Activity
Type Activity Nr Safety Health
Referral 200822088 Yes
Referral 200822070 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $0 $0 $0 $1,000 $0 $1,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 5A0001 02/03/2004 02/21/2004 $1,000 $5,000 $0 02/25/2004 J - ALJ Decision  
2. 01001B Other 19260153 G 02/03/2004 02/21/2004 $0 $0 $0 02/25/2004 J - ALJ Decision  

Investigation Summary

Investigation Nr: 200822146
Event: 08/21/2003
Employee is burned when leaking propane tank ignites

On August 21, 2003, Employee #1 was transporting 20- and 30-pound portable propane fuel tanks in a box truck. Some of the tanks had been leaking and were not secured. When Employee #1, the driver, heard one of the tanks leaking, he entered the back of the truck to identify the leaking tank. While reaching for a tank valve, the vapors ignited. Employee #1 was hospitalized for second- and third-degree burns over his upper body.

Keywords: BURN, LEAK, VAPOR, UNSECURED, TRUCK, VALVE, PROPANE, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306721143 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close