Powered by GoogleTranslate

Inspection Detail

Inspection: 306474669 - Showcase Banner Inc.

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 306474669
Report ID: 0626700
Date Opened: 07/07/2003

Site Address:
Showcase Banner Inc.
10235 Southwest Freeway
Houston, TX 77036

Mailing Address:
14555 Philippine Street,Apt.#227, Houston, TX 77040

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/07/2003

Emphasis:

Case Closed: 10/03/2007


Related Activity
Type Activity Nr Safety Health
Accident 101930915
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $2,250 $0 $0 $250 $0 $2,500
Current Penalty $2,250 $0 $0 $250 $0 $2,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 11/21/2003 11/26/2003 $750 $750 $0 -  
2. 01002 Serious 19260416 A01 11/21/2003 11/26/2003 $750 $750 $0 -  
3. 01003 Serious 19260416 A03 11/21/2003 11/26/2003 $750 $750 $0 -  
4. 02001 Other 19040039 A 11/21/2003 11/26/2003 $250 $250 $0 -  

Investigation Summary

Investigation Nr: 201922887
Event: 07/03/2003
One employee killed, one burned when bucket contacts pow

On July 3, 2003, Employees #1 and #2 were installing a promotional banner on a light pole. Employee #1 was in a bucket truck attempting to maneuver the bucket between the top of the light pole and a high voltage distribution line when he was electrocuted. Employee #2, who was on the ground, sustained electrical burns. The distribution line was less than 10 ft above the light pole. The bucket truck was not insulated.

Keywords: CLEARANCE, INSTALLING, OVERHEAD POWER LINE, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELECTRIC SHOCK, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306474669 Fatality Electric Shock Occupation not reported
2 306474669 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close