Inspection: 306359688 - Pappas Company

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 306359688
Report ID: 0950625
Date Opened: 09/27/2005

Site Address:
Pappas Company
1431 S Lyon
Mendota, CA 93640

Mailing Address:
P O Box 477, Mendota, CA 93640

Union Status: NonUnion

SIC:0723

NAICS: 115114/Postharvest Crop Activities (except Cotton Ginning)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/30/2006

Emphasis: S:Agriculture (Aship)

Case Closed: 12/26/2008


Related Activity
Type Activity Nr Safety Health
Accident 362098469
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $6,750 $0 $0 $840 $0 $7,590
Current Penalty $6,750 $0 $0 $840 $0 $7,590
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 02/02/2006 03/07/2006 $185 $185 $0 -  
2. 01002 Other 3668 A01 02/02/2006 03/07/2006 $280 $280 $0 -  
3. 01003 Other 5155 E01 02/02/2006 03/07/2006 $375 $375 $0 -  
4. 02001 Serious 3662 02/02/2006 03/07/2006 $6,750 $6,750 $0 -  

Investigation Summary

Investigation Nr: 201086865
Event: 08/10/2005
Employee Is Exposed to Carbon Gas While Operating Forklift

On August 10, 2005, Employee #1, a forklift operator, was operating a propane powered forklift, along with 15 other operating forklifts, to place pallets of cantaloupe into a cold room for cold storage processing. The normal operation included forklift operators moving the pallets of cantaloupes from a receiving area to a precool alley and then to the cold room storage. This was the first time that more than six forklifts were operated in the facility room at one time, which resulted in elevated levels of exhaust emissions containing carbon monoxide (CO). After working for approximately seven hours, Employee #1 complained of experiencing severe headache, nausea, and tunnel vision. In addition, he began vomiting and spitting up blood. Emergency services were called and the Fresno County Fire and Rescue team responded. The team measured the CO levels to be 30 ppm at the entrance door and 330 ppm in the middle of the cold room. Work was stopped and the cold room was ordered to be ventilated. Employee #1 was taken to Fresno Community Hospital, where he was hospitalized and treated for asphyxiation. Treatment included receiving oxygen by canula. Upon further investigation, it was revealed that the facility was using an uncalibrated instrument with a faulty oxygen sensor, which only registered 50 ppm of CO in the cold room. Additionally, the employer had failed to provide employees with training in exposure and evacuation procedures for carbon monoxide. The LPG regulator was replaced on the faulty instrument and corrective measures were implemented by the employer, including the installation of CO monitors in the cold room, limiting forklift operations, and providing employee training.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, INHALATION, EQUIPMENT FAILURE, INDUSTRIAL TRUCK, TOXIC FUMES, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306359688 Hospitalized injury Asphyxia Industrial truck and tractor equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.