Inspection Detail
Inspection: 306108614 - Trostel, Ltd.
Inspection Information - Office: Madison Area Office
Site Address:
Trostel, Ltd.
901 Maxwell Street
Lake Geneva, WI 53147
Mailing Address:
, , 00000
Union Status: Union
SIC:3053
NAICS: 339991/ Gasket, Packing, and Sealing Device Manufacturing
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/05/2003
Emphasis: N:Amputate
Case Closed: 12/16/2003
Investigation Summary
On November 12, 2003, Employee #1, a mechanical power press operator, was hand feeding small parts that were approximately 1.75 inches in diameter into a mechanical press. For some reason, the locking nut of the threaded connecting rod on the press, which was used to adjust the pullbacks, vibrated loose. Employee #1's right hand got caught in the machine, severing his right index and middle finger at the first knuckle. Employee #1 was hospitalized and treated for his amputated fingers.
Keywords: SEVERED, AMPUTATED, POWER PRESS, FINGER, VIBRATIONS, PRESS OPERATOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 306108614 | Hospitalized injury | Amputation | Occupation not reported |