Powered by GoogleTranslate

Inspection Detail

Inspection: 306023086 - Sorich Construction, Inc.

Inspection Information - Office: Omaha Area Office

 

Inspection Nr: 306023086
Report ID: 0728900
Date Opened: 11/03/2004

Site Address:
Sorich Construction, Inc.
17601 Storage Road
Omaha, NE 68136

Mailing Address:
17325 O Street, Omaha, NE 68135

Union Status: NonUnion

SIC:1771

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/03/2004

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/28/2005


Related Activity
Type Activity Nr Safety Health
Referral 200055598 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $450 $0 $0 $0 $0 $450
Current Penalty $225 $0 $0 $0 $0 $225
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 11/12/2004 02/18/2005 $225 $450 $0 12/03/2004 F - Formal Settlement  
2. 02001 Other 19101200 E01 11/12/2004 02/18/2005 $0 $0 $0 12/03/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200052363
Event: 11/03/2004
Employee Injured by Falling Form Wall

The owner of the company, Employee #1 and a coworker were building a retaining wall at the end of the employer's building to prevent wash out and run off. The employer is engaged in flat concrete work construction. The owner and the coworker were on the south side of the form work while Employee #1 was on the north side. They had poured approximately 0.75 yards of concrete into the form. The form was made up of 0.75-in. plywood, and 2-in. by 4-in. boards. The wall was 4 ft high and each form section measured 16 ft in length. Each side of the form wall had 2-in. by 4-in. boards for verticals set at two foot centers along the form. The bottom plate of the form was constructed of 2-in. by 4-in. boards and was fastened to the footing at 4 ft intervals. Between each fastener the employer had also placed 0.5-in. rebar 4 in. to 6 in. deep for additional stability of the form. While the owner and the coworker were on the south side of the wall vibrating the concrete between the forms, Employee #1 was on the north side of the form. The form broke in the center of the form at the bottom plate and kicked out hitting Employee #1's foot and pinning it against the dirt wall. The top plate and the rest of the form remained connected to the wall. The owner fearing that he could not get Employee #1 free from the form called emergency services. By the time emergency services arrived Employee #1 had been freed and had sustained only bruises to the foot. Employee #1 was not hospitalized.

Keywords: CONCRETE FORM WORK, WALL, STRUCK BY, FALLING OBJECT, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 306023086 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.