Inspection Detail
Inspection: 305961658 - Leo'S Diving And Marine Service Inc
Inspection Information - Office: Baton Rouge Area Office
Site Address:
Leo'S Diving And Marine Service Inc
29d4m26sn Lat, 89d9m53sw Long.
Venice, LA 70091
Mailing Address:
Po Box 430, Buras, LA 70041
Union Status: NonUnion
SIC:7389
NAICS: 541990/ All Other Professional, Scientific, and Technical Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 10/28/2003
Emphasis: S:Small Businesses
Case Closed: 09/30/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100554492 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100420 A | 02/13/2004 | 03/11/2004 | $0 | $0 | $0 | - | ||
| 2. | 01002A | Other | 19100421 C01 | 02/13/2004 | 02/23/2004 | $0 | $0 | $0 | - | ||
| 3. | 01002B | Other | 19100421 C03 | 02/13/2004 | 02/26/2004 | $0 | $0 | $0 | - | ||
| 4. | 01002C | Other | 19100421 D02 | 02/13/2004 | 02/26/2004 | $0 | $0 | $0 | - | ||
| 5. | 01003A | Other | 19100422 C01 I | 02/13/2004 | 03/03/2004 | $0 | $0 | $0 | - | ||
| 6. | 01003B | Other | 19100422 C02 | 02/13/2004 | 03/03/2004 | $0 | $0 | $0 | - | ||
| 7. | 01004 | Other | 19100430 B01 | 02/13/2004 | 02/26/2004 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 8:45 a.m. on October 24, 2003, Employees #1, #2 and #3 were three members of a four man crew working to repair a 4-in. natural gas intra-field transfer line (900 psi). The line had developed a pinhole leak. The outer coating on the line had become damaged and had fallen off, allowing barnacles to develop on the exposed pipe surface. Employee #1 was the diver and Employees #2 and #3 remained on deck. Employee #1 was using a hatchet to remove the barnacles when the line ruptured, releasing the natural gas. The crew was using a gasoline powered air compressor, located on deck. As the natural gas escaped the water, it ignited resulting in an explosion. Employee #1 was killed while underwater by the explosion. Employees #2 and #3 were severely burned and were transported by helicopter to a local hospital and hospitalized.
Keywords: WORK RULES, DIVING, EXPLOSION, BURN, FLAMMABLE LIQUID, NATURAL GAS, LOCKOUT, GAS LEAK, DIVER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305961658 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 305961658 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |