Inspection Detail
Inspection: 305818361 - Hedges,Inc. Dba Roto-Rooter
Inspection Information - Office: Little Rock Area Office
Site Address:
Hedges,Inc. Dba Roto-Rooter
1705 North 8th Ave.
Paragould, AR 72450
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/03/2003
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 01/28/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100261379 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $6,000 | $0 | $0 | $0 | $0 | $6,000 |
| Current Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100303 B01 | 01/16/2003 | 01/22/2003 | $750 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100304 F04 | 01/16/2003 | 01/22/2003 | $750 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100332 B01 | 01/16/2003 | 01/30/2003 | $750 | $1,500 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100334 A02 II | 01/16/2003 | 01/22/2003 | $750 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
On August 12, 2002, Employee #1 was cleaning a residential waste water drain operating a Roto-Rooter Model Number 4000 machine. Power was from a household 2-wire receptacle through an extension cord. The cord was missing the grounding prong. The nut that secured the non-insulated metal on-off-reverse switch to the cover plate was missing. This allowed the switch to move freely in the switch housing. The switch terminals and wire leads came in contact with the bolt that secured the switch bracket and switch housing to the head casing. The machine became energized and Employee #1 was electrocuted.
Keywords: SHOCK, CORD SET, ELECTROCUTED, GROUND FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305818361 | Fatality | Electric Shock | Plumbers, pipefitters and steamfitters |