Inspection Detail
Inspection: 3057643 - Environmental Air Systems, Inc.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Environmental Air Systems, Inc.
521 Banner Avenue
Greensboro, NC 27415
Mailing Address:
P.O. Box 13006, Greensboro, NC 27415
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/05/1987
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/24/1987
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360767180 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
Current Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260401 A01 | 02/05/1987 | 02/11/1987 | $420 | $420 | $0 | - |
Investigation Summary
An employee was installing heating and air conditioning duct from an electrically powered, hydraulic scissor lift platform. The employee had extended the platform vertically more than 4.9 meters (16 feet). As he was moving the lift another 0.6 to 0.9 meters (2 to 3 feet) to assist a coworker, he received a severe electric shock. He lost consciousness and was hospitalized for his injury. Investigation revealed that an electrical fault in the lift had energized it. The injured employee received the electric shock when he placed one hand on the guardrail of the lift and his other hand on a grounded support rod for a lighting fixture.
Keywords: ELECTRICAL, E GI VII, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, AERIAL LIFT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 3057643 | Hospitalized injury | Electric Shock | Sheetmetal duct installers |