Inspection Detail
Inspection: 305504755 - Perfect Color Printing, Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Perfect Color Printing, Inc.
5731 N.E 14th Avenue
Fort Lauderdale, FL 33334
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2741
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/30/2002
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/12/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100675503 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 1 | 7 | |||
| Current Violations | 6 | 1 | 7 | |||
| Initial Penalty | $13,400 | $0 | $0 | $0 | $0 | $13,400 |
| Current Penalty | $13,400 | $0 | $0 | $0 | $0 | $13,400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100022 B01 | 05/08/2003 | 05/14/2003 | $450 | $450 | $0 | 05/27/2003 | J - ALJ Decision | |
| 2. | 01002A | Serious | 19100212 A01 | 05/08/2003 | 06/04/2003 | $1,050 | $1,050 | $0 | 05/27/2003 | J - ALJ Decision | |
| 3. | 01002B | Serious | 19100219 F01 | 05/08/2003 | 06/04/2003 | $0 | $0 | $0 | 05/27/2003 | J - ALJ Decision | |
| 4. | 01002C | Serious | 19100219 F03 | 05/08/2003 | 06/04/2003 | $0 | $0 | $0 | 05/27/2003 | J - ALJ Decision | |
| 5. | 01003 | Serious | 19100304 B02 | 05/08/2003 | 06/04/2003 | $1,050 | $1,050 | $0 | 05/27/2003 | J - ALJ Decision | |
| 6. | 01004A | Serious | 19100304 F05 IVC | 05/08/2003 | 06/04/2003 | $4,900 | $4,900 | $0 | 05/27/2003 | J - ALJ Decision | |
| 7. | 01004B | Serious | 19100332 B02 | 05/08/2003 | 06/04/2003 | $0 | $0 | $0 | 05/27/2003 | J - ALJ Decision | |
| 8. | 01005 | Serious | 19100305 G01 I | 05/08/2003 | 05/14/2003 | $4,900 | $4,900 | $0 | 05/27/2003 | J - ALJ Decision | |
| 9. | 01006 | Serious | 19100333 B02 I | 05/08/2003 | 06/25/2003 | $1,050 | $1,050 | $0 | 05/27/2003 | J - ALJ Decision | |
| 10. | 02001 | Other | 19101200 E01 | 05/08/2003 | 06/25/2003 | $0 | $0 | $0 | 05/27/2003 | J - ALJ Decision |
Investigation Summary
On December 30, 2002, Employee #1 was working on an ultraviolet (UV) laminating machine. His leg touched an ungrounded UV tank that was electrically charged, due to improper wiring of the tank's pump that was replaced during maintenance work. He was electrocuted and died at the site.
Keywords: INADEQUATE MAINT, ELECTROCUTED, STRUCK AGAINST, ELECTRIC SHOCK, PUMP, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305504755 | Fatality | Electric Shock | Not specified mechanics and repairers |
Translate