Powered by GoogleTranslate

Inspection Detail

Inspection: 305487043 - Equitable Production

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 305487043
Report ID: 0316400
Date Opened: 06/18/2003

Site Address:
Equitable Production
Blue Pennant Natural Gas Pump Station
Whitesville, WV 25209

Mailing Address:
One Oxford Centre 301 Grant Street, Pittsburgh, WV 25209

Union Status: NonUnion

SIC:4922

NAICS: 486210/Pipeline Transportation of Natural Gas


Inspection Type: Accident

Scope: No Insp/Other

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/30/2003

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/02/2003


Related Activity
Type Activity Nr Safety Health
Accident 100630706

Investigation Summary

Investigation Nr: 200630945
Event: 06/17/2003
Employee struck by ruptured gas line

An employee and a coworker were assessing a pipeline when the employee was struck by a release of gas from a ruptured gas line. The gas line was submerged under several feet of water. The employee was struck by a gas from the discharged gas line at approximately 540 psi. The employee died as a result of his injuries. The coworker was also struck by the gas and was transported to the hospital and released shortly after.

Keywords: GAS, RUPTURE, PIPELINE, STRUCK BY, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305487043 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close