Powered by GoogleTranslate

Inspection Detail

Inspection: 305355844 - Laurence Hovinier

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 305355844
Report ID: 0950631
Date Opened: 05/16/2005

Site Address:
Laurence Hovinier
27 Shadowcast
Newport Beach, CA 92660

Mailing Address:
179 N Maple St, Corona, CA 92880

Union Status: NonUnion

SIC:1751

NAICS: 238130/Framing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/08/2005

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/07/2008


Related Activity
Type Activity Nr Safety Health
Accident 362471153
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $36,000 $0 $0 $0 $0 $36,000
Current Penalty $18,335 $0 $0 $0 $0 $18,335
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3650 R 11/08/2005 11/26/2005 $18,000 $18,000 $0 11/23/2005 F - Formal Settlement  
2. 02001 Serious 3650 S06 11/08/2005 11/26/2005 $335 $18,000 $0 11/23/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201146933
Event: 05/16/2005
Employee Is Injured by Falling Wall

On May 16, 2005, Employee #1 and a coworker were raising a framed wall onto the anchor bolts of a concrete slab The wall was about 22 ft high, about 12 ft wide, and framed with 4-in. by 4-in. and 2-in. by 4-in. lumber. A second coworker was operating a GEHL RS8-42 forklift (Employer's Number 39) to lower this wall into place while Employee #1 and the first coworker were guiding the lower end of this wall. An additional truss boom had been attached to the fork structure to extend the boom reach. The extension boom was attached to a horizontal bar on the permanently-attached fork structure with two J-shaped open hooks on the top rear end of the truss boom. The lower rear frame structure of the extension boom rested against the frame structure base of the permanently attached forks. The framed wall was being lifted by ropes attached to the hook at the front end of the extension boom. While the wall was being lowered, the employees noticed that the bolts could not pass through the holes at the bottom of the wall. As they had done several times in the earlier similar situations, the forklift operator was directed to tap the wall down with the boom to align the bolt holes. As this was done, the rear end of the extension boom became detached from the fork structure and fell, striking Employee #1's back and head. He was hospitalized for fractures of his hip, left shoulder, and the lumbar area of his back. Multiple surgeries were performed.

Keywords: ANCHOR, FRACTURE, WALL, BOOM, CARPENTER, WORK RULES, CONSTRUCTION, BACK, INDUSTRIAL TRUCK, HIP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305355844 Hospitalized injury Fracture Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.