Powered by GoogleTranslate

Inspection Detail

Inspection: 305354615 - Sterigenics

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 305354615
Report ID: 0950637
Date Opened: 09/03/2004

Site Address:
Sterigenics
687 Wananaker
Ontario, CA 91761

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8999

NAICS: 561439/Other Business Service Centers (including Copy Shops)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/07/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/08/2006


Related Activity
Type Activity Nr Safety Health
Accident 362461402
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 2
Initial Penalty $36,000 $0 $0 $5,000 $0 $41,000
Current Penalty $9,450 $0 $0 $0 $0 $9,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/07/2005 03/12/2005 $0 $5,000 $0 D - Govt Dismissed Citation has been deleted.
2. 02001 Serious 5189 F01 A 02/07/2005 03/04/2005 $4,725 $18,000 $0 F - Formal Settlement  
3. 03001 Serious 5189 G01 02/07/2005 02/25/2005 $4,725 $18,000 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201146065
Event: 08/19/2004
Four employees are injured in ethylene oxide explosion

At approximately 2:50 p.m. on August 19, 2004, Employees #1, #2, #3, and #4 were working in a scrubber processing unit at Sterigenics in Ontario, CA. Sterigenics utilizes ethylene oxide to sterilize medical equipment. Employees #2, #3, and #4 were performing normal scrubber operation duties, and Employee #1 was working in a supervisory capacity in the mezzanine control room. Chamber number 7 of the scrubber indicated that it had not received an ethylene oxide injection during a validation cycle. Maintenance employees were summoned to troubleshoot the error. After performing various checks on the chamber and system, the maintenance technician and maintenance supervisor calibrated its SEC IR spectrometer to verify the operation of the sterilization number 7 step. This procedure checks the ethylene oxide injection into the sterilization chambers and comprises of several verification phases. The gas inject phase involves the injection of approximately 125 lb of ethylene oxide into the chamber, which is followed by a gas dwell phase. In the vacuum phase, approximately 50 lb of the gas is evacuated from the room to a scrubber, and then the scrubber goes into a vacuum hold phase. The vacuum phase checks the ability of the chamber to maintain vacuum condition. It involves the injection of three gases, including nitrogen and or steam to remove the ethylene oxide from the sterilization chamber, and then the final release, in which a minimal amount of residual ethylene oxide is flushed using air. The residual ethylene oxide and air mixture is sent to a fired catalytic oxidizer that react the residual ethylene oxide to neutralize it. Employee #5 verified that the gas dwell phase and vacuum phase ran correctly and requested the permissive password for authorization to advance the procedure cycles to final release. Employee #5 received the permissive password from Employee #6 and advanced the cycles, bypassing the gas or "safety" washes. Employee #5 then proceeded to open the chamber door on chamber number 7. Opening the chamber door causes a blower to send air through the chamber and blow any residual gases to the fired catalytic oxidizer. A high concentration of approximately 62 lb of ethylene oxide was routed from the sterilization chamber number 7 to the fired catalytic oxidizer, resulting in an explosion and extensive structural and equipment damage. The explosion caused injuries to the employees located near by the scrubber processing unit. Some of the employees received injuries that included contusions and lacerations from flying glass and debris as a result of the explosion.

Keywords: MAINTENANCE, FLAMMABLE VAPORS, ETHYLENE OXIDE, CLEANING, EXPLOSION, LACERATION, GAS LEAK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305354615 Non Hospitalized injury Cut/Laceration Managers and administrators, n.e.c
2 305354615 Non Hospitalized injury Cut/Laceration Occupation not reported
3 305354615 Non Hospitalized injury Cut/Laceration Occupation not reported
4 305354615 Non Hospitalized injury Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.