Inspection Detail
Inspection: 305354029 - Precision Pipeline
Inspection Information - Office: Santa Ana District Office
Site Address:
Precision Pipeline
5419 E Estate Ridge Rd
Anaheim, CA 92808
Mailing Address:
P O Box 876, Alta Loma, CA 91701
Union Status: NonUnion
SIC:1623
NAICS: 237110/Water and Sewer Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/16/2004
Planning Guide: Safety-Construction
Emphasis: S:Construction (Cship)
Case Closed: 02/26/2013
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362469934 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $5,000 | $0 | $5,000 |
Current Penalty | $0 | $0 | $0 | $750 | $0 | $750 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342 A | 11/16/2004 | 11/19/2004 | $750 | $5,000 | $0 | 06/24/2005 | F - Formal Settlement |
Investigation Summary
At 1:06 p.m. on May 26, 2004, Employee #1 was engaged in water improvements in a residential area where the ductile iron metal pipelines had corroded due to soil conditions. He and a coworker were told by their direct supervisor to refit and then reconnect the lateral pipeline to the fire hydrant at a specific road location. The street was partially excavated to expose the lateral pipe. The coworker closed off the gate valve, located in the middle of the street, which is used to shut down the fire hydrant in the event of a vehicle hitting it or when the hydrant is serviced. The lateral pipeline was cut and the end closest to the gate valve was capped. However, between 7 and 8 ft back, buried in the street, the gasket between the gate valve and the lateral pipe failed. Pressure built up inside of the capped lateral pipe and the cap blew off. Employee #1 was in the excavation preparing to connect a 45-degree elbow when the end cap on the pipe struck him in the back of his left leg. The impact pushed him forward, and his left leg smashed into the cut end of the existing lateral pipe. Employee #1 was transported to the hospital, where he underwent orthopedic reconstruction surgery on his left leg.
Keywords: FRACTURE, PIPE PLUG, INSTALLING, REPAIR, CONSTRUCTION, HIGH PRESSURE, STRUCK BY, FLYING OBJECT, PRESSURE RELEASE, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 305354029 | Hospitalized injury | Fracture | Construction laborers |