Powered by GoogleTranslate

Inspection Detail

Inspection: 305353831 - Handpiece Parts & Products

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 305353831
Report ID: 0950631
Date Opened: 05/03/2004

Site Address:
Handpiece Parts & Products
707 W Angus Ave
Orange, CA 92868

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3843

NAICS: 339114/Dental Equipment and Supplies Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/08/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/22/2006


Related Activity
Type Activity Nr Safety Health
Accident 362473548
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $6,100 $0 $6,100
Current Penalty $0 $0 $0 $6,100 $0 $6,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/08/2004 10/31/2004 $5,000 $5,000 $0 -  
2. 01002 Other 3203 A 10/08/2004 10/31/2004 $275 $275 $0 -  
3. 01003 Other 3314 F 10/08/2004 10/31/2004 $275 $275 $0 -  
4. 01004 Other 4233 10/08/2004 10/31/2004 $550 $550 $0 -  

Investigation Summary

Investigation Nr: 201145406
Event: 04/21/2004
Employee's finger amputated in lathe machine

On April 21, 2004, Employee #1 was working with a 12-ft long and about 0.25-in.-thick hex rod. He was using a CNC lathe, manufactured by Miyano Company, Model BNC-12, Serial Number 86BN120285. This machine took in a metal rod and formed small dental tools. The feed mechanism on this machine consisted of a trough shaped channel and could accommodate up to 20-ft-long bar stock. After he fed this 12-ft-long stock into the machine, the part of the stock, which was not covered by the PVC tube was jumping up and down while rotating in the open trough and was making excessive noise. Employee #1 thought that he could stop this unintended movement of the stock by pushing the feed unit against the lathe to get a better alignment of the stock. While he was trying to push the feed unit, he was holding a rag in his right hand, which was caught by the rotating stock. His right middle finger was caught and crushed between the vibrating bar stock and the trough channel. Employee #1 was taken to Saint Joseph Hospital in Orange, California, and his right middle finger was amputated at the second knuckle from the top.

Keywords: LATHE, ROTATING PARTS, AMPUTATED, FINGER, CAUGHT BY, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305353831 Hospitalized injury Amputation Lathe and turning machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close