Inspection Detail
Inspection: 305353336 - Pacific Exteriors Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Pacific Exteriors Inc
1325 E 17th St
Santa Ana, CA 92705
Mailing Address:
13911-B Enterprise Dr, Garden Grove, CA 92843
Union Status: NonUnion
SIC:1742
NAICS: 238310/Drywall and Insulation Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/10/2004
Emphasis: S:Construction (Cship)
Case Closed: 10/11/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362472532 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $650 | $0 | $650 |
| Current Penalty | $0 | $0 | $0 | $650 | $0 | $650 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1644 A06 | 06/11/2004 | 06/16/2004 | $650 | $650 | $0 | - |
Investigation Summary
On February 16, 2004, Employee #1 and coworkers were applying stucco to the exterior of an 18-foot-high commercial building that was under construction. A two-tier tube and coupler scaffolding encircled the perimeter of the building, with the lowest tier measuring 14.17 feet above the ground. Additionally, there was a decorative granite strip, approximately 15 feet above the ground that required to be masked before stucco was applied. As Employee #1 sat on the lower tier of the scaffolding and was covering the granite strip with a plastic sheet and masking tape, he fell. For some reason, he had leaned back into the midrail of the guardrail and it came loose, causing him to fall. Employee #1 was transported to Western Medical Center in Santa Ana and pronounced dead. A detailed investigation revealed that there was no defect with the coupling or pin of the vertical member of the guardrail, but they were not properly locked. The scaffolding contractor set up the scaffolds three weeks before the accident and only a visual inspection was conducted prior to Employee #1 and his coworkers starting work.
Keywords: HEAD, CONSTRUCTION, FALL, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305353336 | Fatality | Other | Plasterers |