Inspection Detail
Inspection: 305352700 - Aaa Refinishing Corporation
Inspection Information - Office: Santa Ana District Office
Site Address:
Aaa Refinishing Corporation
12091 Bayport St
Garden Grove, CA 92840
Mailing Address:
11001 Fleetwood St, Sun Valley, CA 91352
Union Status: NonUnion
SIC:1799
NAICS: 238390/Other Building Finishing Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/12/2004
Emphasis: S:Construction (Cship)
Case Closed: 11/12/2004
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362368888 |
Investigation Summary
At approximately 5:00 p.m. on October 28, 2003, Employee #1, a full time employee, was refinishing a sink or bathtub in a residential dwelling. When refinishing a sink or bathtub employees of this company clean and spray paint the sink or bathtub with an epoxy/polymer paint first and then after drying spray with a polyurethane topcoat. Employees use Wagner 200 High Volume Low Pressure Sprayers, compressors, and 6-inch rib-vent exhaust fans for refinishing. Employees are to set the exhaust fans up inside the work area and the compressor outside the kitchen or bathroom. Employees are required by the employer to wear full-face respirators when using a spray gun. Employee #1 set up his compressor inside the work area and began spraying, failing to set up the exhaust fan. Due to improper ventilation, the air in the room became saturated with highly flammable vapors and was ignited by the hot turbine of the compressor. Employee #1 sustained burns to his upper body and was hospitalized for over 24 hours.
Keywords: BURN, COMPRESSOR, VAPOR, VENTILATION, FLAMMABLE LIQUID, SPRAY PAINTING, PAINT, EXPLOSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 305352700 | Hospitalized injury | Burn/Scald(Heat) | Technicians, n.e.c. |