Inspection Detail
Inspection: 305352643 - Kca Electronics Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Kca Electronics Inc
241 N Cresecent Wy
Anaheim, CA 92808
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3672
NAICS: 334412/Bare Printed Circuit Board Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/26/2004
Emphasis:
Case Closed: 09/13/2010
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362368318 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $8,000 | $0 | $8,000 |
Current Penalty | $0 | $0 | $0 | $1,200 | $0 | $1,200 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342 A | 04/26/2004 | 05/29/2004 | $0 | $5,000 | $0 | 06/25/2004 | J - ALJ Decision | Citation has been deleted. |
2. | 01002 | Other | 3203 A04 | 04/26/2004 | 05/29/2004 | $0 | $600 | $0 | 06/25/2004 | J - ALJ Decision | Citation has been deleted. |
3. | 01003 | Other | 5141 A | 04/26/2004 | 05/29/2004 | $0 | $600 | $0 | 06/25/2004 | J - ALJ Decision | Citation has been deleted. |
4. | 01004 | Other | 5141 C | 04/26/2004 | 05/29/2004 | $600 | $600 | $0 | 06/25/2004 | J - ALJ Decision | |
5. | 01005 | Other | 5155 E01 | 04/26/2004 | 05/29/2004 | $0 | $600 | $0 | 06/25/2004 | J - ALJ Decision | Citation has been deleted. |
6. | 01006 | Other | 5194 H01 | 04/26/2004 | 05/29/2004 | $600 | $600 | $0 | 06/25/2004 | J - ALJ Decision |
Investigation Summary
At approximately 6:00 a.m. on October 13, 2003, an employee was working in the maintenance shop of an electronic circuit board manufacturer. The employee started to disassemble and clean a sodium permanganate chemical solution filter assembly on a work bench in preparation for rebuilding the assembly. Solid material on the filters had a charcoal black color and was in both large pieces, like rock, and also in much fine material, dust. Lots of dust got onto the floor of the maintenance shop adjacent to the work bench. A coworker told the employee to clean the dust from the floor of the maintenance shop. The employee used a broom and dust pan to remove this chemical from the shop floor. The employee started to feel sick and began to show some unspecified adverse effects around 10:00 a.m. The employee was hospitalized and treated for systemic poisoning.
Keywords: DUST, INHALATION, POISONING, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 305352643 | Hospitalized injury | Poisoning(Systemic) | Not specified mechanics and repairers |