Powered by GoogleTranslate

Inspection Detail

Inspection: 305352635 - Friar Tux Shop

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 305352635
Report ID: 0950631
Date Opened: 11/03/2003

Site Address:
Friar Tux Shop
1711 S Claudina Wy
Anaheim, CA 92805

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7299

NAICS: 532220/Formal Wear and Costume Rental


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/19/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362367328
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 2
Initial Penalty $24,750 $0 $0 $5,000 $0 $29,750
Current Penalty $18,675 $0 $0 $0 $0 $18,675
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/19/2004 03/24/2004 $0 $5,000 $0 09/30/2004 F - Formal Settlement Citation has been deleted.
2. 02001 Serious 4492 03/19/2004 04/11/2004 $675 $6,750 $0 09/30/2004 F - Formal Settlement  
3. 03001 Serious 3314 A 03/19/2004 04/11/2005 $18,000 $18,000 $0 09/30/2004 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201144680
Event: 10/29/2003
Employee burns hand when it is caught in clothes press

On October 29, 2003, an employee was working for a formal garment rental company. Operations included cleaning and ironing clothes. An accident occurred on a shirt collar and cuff press manufactured by Ajax Company, Model CCW, and serial number SPHF 12622423. The machine was rated for a maximum of 125 pounds per square inch at 650 degrees F. The press consisted of top and bottom dies to press the shirt collar and cuffs. The bottom die was stationary and had three contoured ridges. The top spring-loaded hinged die had three complementing contoured concave shapes to fit on the three ridges of the bottom die. These dies were closed with a set of two-hand control buttons located at the front of the machine. Opening the dies was accomplished by pressing either of the two additional buttons located at the front of the machine. At the end of her normal shift, the employee cleaned the dies. The dies were in the open position, and the employee reached in between the dies to grab a towel resting on the machine frame located behind the dies. Due to some unknown reason, the dies closed on her right hand and right forearm. She was able to release her arm by pressing a button with her left hand. The employee suffered a third-degree burn, extending from her right palm to the middle of her right forearm, and was hospitalized for 15 days.

Keywords: BURN, DIE, HAND CONTROL, FOREARM, DRY CLEANING, CAUGHT BETWEEN, PRESS OPERATOR, HAND, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305352635 Hospitalized injury Burn/Scald(Heat) Launderers and ironers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close