Powered by GoogleTranslate

Inspection Detail

Inspection: 305216483 - Pignato Masonry, Inc.

Inspection Information - Office: Chicago South Area Office

 

Inspection Nr: 305216483
Report ID: 0521700
Date Opened: 07/17/2002

Site Address:
Pignato Masonry, Inc.
6610 W. Highland Drive
Palos Heights, IL 60463

Mailing Address:
18813 S. 82nd Avenue Unit #5, Mokena, IL 60448

Union Status: Union

SIC:1741

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/18/2002

Planning Guide: Safety-Construction

Emphasis: S:Construction

Case Closed: 10/17/2002


Related Activity
Type Activity Nr Safety Health
Accident 100031434
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $4,350 $0 $0 $0 $0 $4,350
Current Penalty $2,200 $0 $0 $0 $0 $2,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 F06 10/01/2002 10/04/2002 $1,000 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260405 A02 III 10/01/2002 10/04/2002 $1,000 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19260451 C02 10/01/2002 10/04/2002 $100 $600 $0 I - Informal Settlement  
4. 01004 Serious 19260454 A01 10/01/2002 10/04/2002 $100 $750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200031524
Event: 07/17/2002
Employee killed when scaffold energized by cut extension cor

On July 17, 2002, Employer #1, a laborer working for a masonry company, was entering a room where a tubular-framed scaffold had been erected. One of the scaffold legs had been set on top of an extension cord that was being used to power a industrial fan on the opposite side of the room. The extension cord ran underneath the scaffold's leg near the permanent outlet on the west end of the room and the cord was touching the scaffold at various points leading to the outlet. The weight of the scaffold cut through the extension cord, energizing the scaffold. When Employee #1 entered the room and passed through the door frame and the scaffold, he was electrocuted.

Keywords: SEVERED, WORK RULES, CORD SET, ELECTROCUTED, CONSTRUCTION, ELEC CIRC PART--MISC, SCAFFOLD, TUBULAR SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305216483 Fatality Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.