Powered by GoogleTranslate

Inspection Detail

Inspection: 305114795 - Ultimate Systems, Ltd.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 305114795
Report ID: 0524700
Date Opened: 08/16/2002

Site Address:
Ultimate Systems, Ltd.
1430 N. Main St
Delphos, OH 45833

Mailing Address:
P.O. Box 465, Delphos, OH 45833

Union Status: NonUnion

SIC:3069

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/15/2002

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/14/2003


Related Activity
Type Activity Nr Safety Health
Accident 102103785
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 3 2 5
Initial Penalty $7,500 $0 $0 $0 $0 $7,500
Current Penalty $4,000 $0 $0 $0 $0 $4,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 IIB 12/04/2002 01/23/2003 $1,500 $1,500 $0 12/23/2002 R - Review Commission  
2. 01002 Other 19100147 C06 I 12/04/2002 12/31/2002 $0 $1,500 $0 12/23/2002 R - Review Commission  
3. 01003 Other 19100147 C07 I 11/29/2002 01/17/2003 $0 $1,500 $0 12/23/2002 R - Review Commission  
4. 01004 Serious 19100147 D06 12/04/2002 12/16/2002 $1,500 $1,500 $0 12/23/2002 R - Review Commission  
5. 01005A Serious 19100212 A01 12/04/2002 01/15/2003 $1,000 $1,500 $0 12/23/2002 R - Review Commission  
6. 01005B Serious 19100212 A01 12/04/2002 01/15/2003 $0 $0 $0 12/23/2002 R - Review Commission  

Investigation Summary

Investigation Nr: 202086088
Event: 08/15/2002
Employee Killed When Hopper Doors Inside Mixer Close on Him

Employee #1 was cleaning the inside of a rubber mixing machine when apparently a directional air valve malfunctioned causing the weigh hopper doors to close on him. He was extricated by the fire department and emergency medical services. At the direction of the coroner he was transported to St. Rita's Hospital, where he was pronounced dead.

Keywords: HOPPER DOOR, CLEANING, MIXER, LOCKOUT, VALVE, STRUCK BY, DOOR, MECH MALFUNCTION, HOPPER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305114795 Fatality Other Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close