Powered by GoogleTranslate

Inspection Detail

Inspection: 305084766 - Williams Steel Erection Co., Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 305084766
Report ID: 0352440
Date Opened: 01/14/2002

Site Address:
Williams Steel Erection Co., Inc.
Howard Community College
Columbia, MD 21044

Mailing Address:
8624 J.D. Reading Drive, Manassas, VA 20109

Union Status: Union

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/22/2002

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/06/2002


Related Activity
Type Activity Nr Safety Health
Accident 100969286

Investigation Summary

Investigation Nr: 202329058
Event: 01/14/2002
Tower crane collapse

On January 14, 2002, a crane operator working for Williams Steel Erection Co., Inc. attempted to lift four pieces of steel that weighed a total of 13,818 pounds up to steelworkers. The crane was rated for 7,470 pounds at a radius of 100 ft and at 9,220 pounds at a radius of 90 ft. The crane was at a radius between 90 ft to 100 ft. The crane lost its load and the pieces of steel fell to the ground and the crane flipped over on its side. No employee was injured in the accident.

Keywords: STEEL, COLLAPSE, TOWER CRANE, STEEL ERECTION, CRANE OPERATOR, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305084766 Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.