Powered by GoogleTranslate

Inspection Detail

Inspection: 305030207 - Marlatt Construction, Inc.

Inspection Information - Office: Wichita Area Office

 

Inspection Nr: 305030207
Report ID: 0729700
Date Opened: 09/14/2002

Site Address:
Marlatt Construction, Inc.
1300 Main
Atchison, KS 66002

Mailing Address:
17588 274 Road, Atchison, KS 66002

Union Status: NonUnion

SIC:1799

NAICS: 562910/Remediation Services


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/07/2003

Emphasis: S:Construction

Case Closed: 03/25/2003


Related Activity
Type Activity Nr Safety Health
Accident 101342376
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $1,950 $0 $0 $0 $0 $1,950
Current Penalty $1,200 $0 $0 $0 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260451 B01 02/21/2003 04/09/2003 $1,000 $1,500 $0 I - Informal Settlement  
2. 01001B Serious 19260451 G01 02/21/2003 02/26/2003 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19260451 E01 02/21/2003 02/26/2003 $200 $450 $0 I - Informal Settlement  
4. 02001 Other 19101200 E01 02/21/2003 04/09/2003 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201342649
Event: 09/13/2002
Two employees are burned in distillery explosion

On September 13, 2002, Employees #1 and #2 were working in the vicinity of the A-still when it was started. One of the manhole covers in the absorption column was apparently open and flammable alcohol vapors escaped and exploded in flame. Employees #1 and #2 both sustained burns, for which they were hospitalized. Previously, the absorption column had been opened to inspect the corn grits process and apparently one of the manholes had not been closed. No lockout and tagout procedures were used when the absorption column was opened, and there was no verification process in place to ensure that all the manhole covers were closed before the still was activated.

Keywords: COVER, FLAMMABLE VAPORS, WORK RULES, EXPLOSION, BURN, ALCOHOL, FIRE, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305030207 Hospitalized injury Burn(Chemical) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close