Powered by GoogleTranslate

Inspection Detail

Inspection: 305028441 - Chito'S Well Service, Llc

Inspection Information - Office: Wichita Area Office

 

Inspection Nr: 305028441
Report ID: 0729700
Date Opened: 07/12/2002

Site Address:
Chito'S Well Service, Llc
800 North Oak
Stockton, KS 67669

Mailing Address:
1312 S. Washington, Plainville, KS 67665

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/30/2002

Emphasis: S:Amputations

Case Closed: 12/02/2002


Related Activity
Type Activity Nr Safety Health
Accident 101342251
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $5,400 $0 $0 $1,000 $0 $6,400
Current Penalty $5,400 $0 $0 $1,000 $0 $6,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100151 B 09/30/2002 11/18/2002 $450 $450 $0 -  
2. 01002 Serious 19100332 B02 09/30/2002 11/18/2002 $1,500 $1,500 $0 -  
3. 01003A Serious 19100333 C03 09/30/2002 10/08/2002 $1,500 $1,500 $0 -  
4. 01003B Serious 19100333 C03 IIIA 09/30/2002 10/08/2002 $0 $0 $0 -  
5. 01003C Serious 19100333 C03 IIIB 09/30/2002 11/18/2002 $0 $0 $0 -  
6. 01004 Serious 19100335 B01 09/30/2002 10/25/2002 $1,500 $1,500 $0 -  
7. 01005A Serious 19101200 E01 09/30/2002 11/18/2002 $450 $450 $0 -  
8. 01005B Serious 19101200 H01 09/30/2002 11/18/2002 $0 $0 $0 -  
9. 01005C Serious 19101200 G08 09/30/2002 11/18/2002 $0 $0 $0 -  
10. 02001 Other 19040039 A 09/30/2002 10/03/2002 $1,000 $1,000 $0 -  

Investigation Summary

Investigation Nr: 201342557
Event: 07/08/2002
One Employee Killed, Two Injured When Contacting Power Line

On July 8, 2002, Employees #1, #2, and #3 were, rigging down the well service mast boom on a truck. Employees #1, #2, and #3 had just installed a new push rod on the oil well. As the vehicle mast was being lowered to the truck, the mast boom came with 10 ft of an overhead power line carrying 7200 volts. Employee #1 was controlling the steel cable lines at the rear of the truck, when the steel cable lines contacted the power line. Employee #1 was electrocuted. Employees #2 and #3 were operating the brake and clutch on the side of the truck suffered unknown injures. Employees #2 and #3 were taken to the hospital where they were treated released.

Keywords: RIGGING, OVERHEAD POWER LINE, BOOM, STEEL TUBE, ELECTROCUTED, TRUCK, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 305028441 Fatality Electric Shock Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.