Powered by GoogleTranslate

Inspection Detail

Inspection: 304787948 - Seamless Gutters, Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 304787948
Report ID: 0751910
Date Opened: 09/20/2001

Site Address:
Seamless Gutters, Inc.
2720 14th Street
Rock Valley, IA 51247

Mailing Address:
2999 310th Street, Hull, IA 51239

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/21/2001

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/04/2001


Related Activity
Type Activity Nr Safety Health
Accident 361879141
Referral 200521748 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,050 $0 $0 $1,500 $0 $2,550
Current Penalty $525 $0 $0 $500 $0 $1,025
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 B01 I 10/09/2001 11/27/2001 $525 $1,050 $0 I - Informal Settlement  
2. 02001 Other 40008 10/09/2001 10/15/2001 $500 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200524395
Event: 07/27/2001
Employee Receives Shock from Contact with Energized Parts

Employee #1 was on the back side of a house using a Rockwell saw (Model Number 34-010) to cut and remove damaged gutters the jobsite. It had rained off and on that morning. Employee #1 was wet, the ground where the saw was located was wet, and the saw was not plugged into an outlet protected by a ground-fault circuit interrupter. When Employee #1 touched the saw, he was electrocuted. Two coworkers who had been working on other sides of the house saw Employee #1 lying on his back with his hand still on the saw and the saw still running. One unplugged the saw from the extension cord, and the other called emergency medical services.

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, CURRENT LEAKAGE, ELECTRIC SAW, SAW, E C, ELEC PORT TOOL--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304787948 Fatality Electric Shock Helpers, construction trades
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close