Powered by GoogleTranslate

Inspection Detail

Inspection: 304710049 - Krb Contractors

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 304710049
Report ID: 0352430
Date Opened: 10/22/2001

Site Address:
Krb Contractors
333 Nicodemus Road
Owings Mills, MD 21117

Mailing Address:
1608 Crestlight Court, Finksburg, MD 21048

Union Status: NonUnion

SIC:1521

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/01/2001

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/24/2002


Related Activity
Type Activity Nr Safety Health
Accident 100969005
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $11,250 $0 $0 $0 $0 $11,250
Current Penalty $2,250 $0 $0 $0 $0 $2,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 11/27/2001 12/30/2001 $500 $1,050 $0 12/10/2001 F - Formal Settlement  
2. 01002 Serious 19260021 B02 11/27/2001 12/30/2001 $500 $3,050 $0 12/10/2001 F - Formal Settlement  
3. 02001 Serious 19260416 A01 11/27/2001 11/30/2001 $500 $3,050 $0 12/10/2001 F - Formal Settlement  
4. 02002 Serious 19260416 A03 11/27/2001 11/30/2001 $500 $3,050 $0 12/10/2001 F - Formal Settlement  
5. 03001A Serious 19260501 B11 11/27/2001 11/30/2001 $250 $1,050 $0 12/10/2001 F - Formal Settlement  
6. 03001B Serious 19260503 A01 11/27/2001 12/30/2001 $0 $0 $0 12/10/2001 F - Formal Settlement  
7. 04001 Other 19260503 B01 11/27/2001 12/30/2001 $0 $0 $0 12/10/2001 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202329280
Event: 10/19/2001
One killed, one burned when ladder lift contacts power line

On October 19, 2001, Employees #1 and #2 were starting to clean up after completing a fiberglass shingle roof replacementon a two-story single-family home. Earlier in the day, a 28 ft long ladder lift had been placed at a point approximately 9 ft 8 in. from the dwelling. There was also a 28 ft 7 in. high power line located approximately 11 ft in the front of the dwelling. The employees were lowering the ladder left from the 21 ft high eave when the top of the lift contacted the energized 13-kilovolt power line. Employee #1 was electrocuted. Employee #2 suffered burns on his hands, for which he was treated and released. The employer did not have a safety program in effect, and no training was provided to the employees. The employer did not check for the presence of energized lines in the area, and employees were permitted to work in the area where the lift could contact the energized lines.

Keywords: BURN, CLEARANCE, OVERHEAD POWER LINE, ROOF, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, UNTRAINED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304710049 Fatality Electric Shock Carpenters
2 304710049 Non Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.