Inspection Detail
Inspection: 304706989 - National Riggers & Erectors, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
National Riggers & Erectors, Inc.
5483 Ducks Rd.
Orlando, FL 33511
Mailing Address:
1460 Jibb St., Plymouth, MI 48170
Union Status: Union
SIC:1791
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/20/2001
Emphasis: L:Fall, L:Flcare, S:Construction, S:Construction Fatalities
Case Closed: 02/19/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102305273 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260104 B | 12/31/2001 | 01/07/2002 | $7,000 | $7,000 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
Employee #1 was decking a metal roof, when he fell 60 ft. Employee #1 was wearing a full body harness and a self-retracting lanyard, however, the lanyard did not activate until he had fallen 29 ft. At that time the self retracting lanyard cable broke and Employee #1 fell another 31 ft. Employee #1 died.
Keywords: ROOF, WIRE ROPE, LANYARD, METAL DECKING, FALL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 304706989 | Fatality | Other | Occupation not reported |