Inspection: 304631930 - Shelton & Sons Insulation And Roofing Co.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 304631930
Report ID: 0418100
Date Opened: 07/31/2002

Site Address:
Shelton & Sons Insulation And Roofing Co.
20 Central Ave (Ga 17)
Canon, GA 30520

Mailing Address:
484 Gosnell Hutto Road, Danielsville, GA 30633

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/01/2002

Emphasis: S:Construction Fatalities

Case Closed: 10/24/2002


Related Activity
Type Activity Nr Safety Health
Accident 101281657
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $4,900 $0 $0 $0 $0 $4,900
Current Penalty $100 $0 $0 $0 $0 $100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 10/08/2002 10/18/2002 $100 $4,900 $0 I - Informal Settlement  
2. 01001B Serious 19260416 A01 10/08/2002 10/18/2002 $0 $0 $0 -  
3. 01001C Serious 19260416 A03 10/08/2002 10/18/2002 $0 $0 $0 -  
4. 01001D Serious 19261053 B12 10/08/2002 10/18/2002 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201281409
Event: 07/26/2002
Employee killed when metal ladder contacts power lines

On July 26, 2002, Employee #1 and coworkers were part of a roofing subcontractor crew that was engaged in roof work at a church restoration project in Canon, GA. Several workers were moving a 40 ft tall aluminum extension ladder when it contacted residential power lines located within 10 ft 6 in. of the church. Employee #1 was electrocuted, and two of his coworkers were injured.

Keywords: CLEARANCE, OVERHEAD POWER LINE, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, METAL LADDER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304631930 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.