Powered by GoogleTranslate

Inspection Detail

Inspection: 304615701 - Ice Chalets Inc

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 304615701
Report ID: 1054191
Date Opened: 08/07/2001

Site Address:
Ice Chalets Inc
12000 Se 82nd Ave #1085
Portland, OR 97266

Mailing Address:
Ct Corp System 388 State St Ste 420, Salem, OR 97301

Union Status: NonUnion

SIC:7999

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/21/2001

Emphasis:

Case Closed: 10/03/2002


Related Activity
Type Activity Nr Safety Health
Inspection 304615685
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $450 $0 $0 $0 $0 $450
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 701076001 C 10/19/2001 11/19/2001 $0 $450 $0 11/05/2001 L - State Settlement  
2. 02002 Other 701070501 10/19/2001 08/07/2001 $0 $0 $0 11/05/2001 L - State Settlement  
3. 02003A Other 701076505 A A 10/19/2001 10/29/2001 $0 $0 $0 11/05/2001 L - State Settlement  
4. 02003B Other 701076506 D AI 10/19/2001 10/29/2001 $0 $0 $0 11/05/2001 L - State Settlement  

Investigation Summary

Investigation Nr: 201632049
Event: 08/05/2001
Seven employees exposed to leaking freon gas

On August 5, 2001, during routine ice rink maintenance, the blade of the Zamboni ice making machine hit a refrigeration pipe, laid right below the surface of the ice, on north side of the rink. It ruptured the pipe and caused the release of the pressurized Freon 22 into the air above the "Ice Chalet" skating rink at Clackamas Town Center. Security personnel from Valor Security Service Company got involved in the evacuation of the building and seven guards got exposed to Freon gas. They were then sent to Sunnyside Kaiser Hospital for the evaluation of their symptoms, which included coughing, shortness of breath and light-headedness. The seven Security Officers were released from the hospital a couple hours later and none of them were admitted to the hospital.

Keywords: LEAK, SECURITY GUARD, FREON, COUGH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304615701 Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close